Constructor
new Cea608DataChannel(fieldNum, channelNum)
Parameters:
Name | Type | Description |
---|---|---|
fieldNum |
number | Field number. |
channelNum |
number | Channel number. |
- Source:
Members
MiscCmd_ :number
Command codes.
Type:
- number
Properties:
Name | Value | Type | Description |
---|---|---|---|
RCL |
32 | number | |
BS |
33 | number | |
AOD |
34 | number | |
AON |
35 | number | |
DER |
36 | number | |
RU2 |
37 | number | |
RU3 |
38 | number | |
RU4 |
39 | number | |
FON |
40 | number | |
RDC |
41 | number | |
TR |
42 | number | |
RTD |
43 | number | |
EDM |
44 | number | |
CR |
45 | number | |
ENM |
46 | number | |
EOC |
47 | number |
- Source:
lastcp_ :number
Last control pair, 16 bits representing byte 1 and byte 2
Type:
- number
- Source:
prevEndTime_ :number
End time of the previous caption, serves as start time of next caption.
Type:
- number
- Source:
text_ :shaka.cea.Cea608Memory
Text buffer for CEA-608 "text mode". Although, we don't emit text mode.
So, this buffer serves as a no-op placeholder, just in case we receive
captions that toggle text mode.
Type:
- Source:
Methods
isControlCode(b1) → {boolean}
Checks if the data contains a control code.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
- Source:
Returns:
- Type
- boolean
isXdsControlCode(b1) → {boolean}
Checks if the data contains a XDS control code.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
- Source:
Returns:
- Type
- boolean
controlBackgroundAttribute_(b1, b2)
Background attribute control code handler.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte #1 |
b2 |
number | Byte #2. |
- Source:
controlCr_(pts) → {shaka.extern.ICaptionDecoder.ClosedCaption}
Handles CR - Carriage Return (Start new row).
CR only affects scroll windows (Rollup and Text modes).
Any currently buffered line needs to be emitted, along
with a window scroll action.
Parameters:
Name | Type | Description |
---|---|---|
pts |
number | in seconds. |
- Source:
Returns:
controlEdm_(pts) → {shaka.extern.ICaptionDecoder.ClosedCaption}
Handles EDM - Erase Displayed Mem
Mode check:
EDM affects all captioning modes (but not Text mode);
Parameters:
Name | Type | Description |
---|---|---|
pts |
number |
- Source:
Returns:
controlEoc_(pts) → {shaka.extern.ICaptionDecoder.ClosedCaption}
Handles EOC - End Of Caption (flip mem)
This forces Pop-On mode, and swaps the displayed and nondisplayed memories.
Parameters:
Name | Type | Description |
---|---|---|
pts |
number |
- Source:
Returns:
controlMidrow_(b2)
Mid-Row control code handler.
Parameters:
Name | Type | Description |
---|---|---|
b2 |
number | Byte #2. |
- Source:
controlMiscellaneous_(ccPacketnon-null) → {shaka.extern.ICaptionDecoder.ClosedCaption}
The Cea608DataChannel control methods implement all CC control operations.
Parameters:
Name | Type | Description |
---|---|---|
ccPacket |
shaka.cea.Cea608DataChannel.Cea608Packet |
- Source:
Returns:
controlPac_(b1, b2)
PAC - Preamble Address Code.
b1 is of the form |P|0|0|1|C|0|ROW|
b2 is of the form |P|1|N|ATTRIBUTE|U|
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
controlRcl_()
Handles RCL - Resume Caption Loading
Initiates Pop-On style captioning. No need to force anything out upon
entering Pop-On mode because it does not affect the current display.
- Source:
controlRdc_(pts)
Handles RDC - Resume Direct Captions. Initiates Paint-On captioning mode.
RDC does not affect current display, so nothing needs to be forced out yet.
Parameters:
Name | Type | Description |
---|---|---|
pts |
number | in seconds |
- Source:
controlRtd_()
Handles RTD - Resume Text Display.
Resumes text mode. No need to force anything out, because Text Mode doesn't
affect current display. Also, this decoder does not emit Text Mode anyway.
- Source:
controlRu_(scrollSize, pts) → {shaka.extern.ICaptionDecoder.ClosedCaption}
Handles RU2, RU3, RU4 - Roll-Up, N rows.
If in TEXT, POPON or PAINTON, any displayed captions are erased.
This means must force emit entire display buffer.
Parameters:
Name | Type | Description |
---|---|---|
scrollSize |
number | New scroll window size. |
pts |
number |
- Source:
Returns:
controlTr_()
Handles TR - Text Restart.
Clears text buffer and resumes Text Mode.
- Source:
firstPts(pts)
Set the initial PTS, which may not be 0 if we start decoding at a later
point in the stream. Without this, the first cue's startTime can be way
off.
Parameters:
Name | Type | Description |
---|---|---|
pts |
number |
- Source:
handleBasicNorthAmericanChar(b1, b2)
Handles a Basic North American byte pair.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
handleControlCode(ccPacketnon-null) → {shaka.extern.ICaptionDecoder.ClosedCaption}
Decodes control code.
Three types of control codes:
Preamble Address Codes, Mid-Row Codes, and Miscellaneous Control Codes.
Parameters:
Name | Type | Description |
---|---|---|
ccPacket |
shaka.cea.Cea608DataChannel.Cea608Packet |
- Source:
Returns:
handleExtendedWesternEuropeanChar_(b1, b2)
Handles an Extended Western European byte pair.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
isBackgroundAttribute_(b1, b2) → {boolean}
Checks if this is a background attribute control code.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
Returns:
- Type
- boolean
isExtendedWesternEuropeanChar_(b1, b2) → {boolean}
Checks if the character is in the Extended Western European char. set.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
Returns:
- Type
- boolean
isMidrowStyleChange_(b1, b2) → {boolean}
Checks if this is a Midrow style change control code.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
Returns:
- Type
- boolean
isMiscellaneous_(b1, b2) → {boolean}
Checks if this is a Miscellaneous control code.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
Returns:
- Type
- boolean
isPAC_(b1, b2) → {boolean}
Checks if this is a PAC control code.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
Returns:
- Type
- boolean
isSpecialNorthAmericanChar_(b1, b2) → {boolean}
Checks if the character is in the Special North American char. set.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
Returns:
- Type
- boolean
pacToRow_(b1, b2) → {number}
Gets the row index from a Preamble Address Code byte pair.
Parameters:
Name | Type | Description |
---|---|---|
b1 |
number | Byte 1. |
b2 |
number | Byte 2. |
- Source:
Returns:
Row index.
- Type
- number
Type Definitions
Cea608Packet
CEA closed captions packet.
Type:
- {pts: number, type: number, ccData1: number, ccData2: number, order: number}
Properties:
Name | Type | Description |
---|---|---|
pts |
number | Presentation timestamp (in second) at which this packet was received. |
type |
number | Type of the packet. Either 0 or 1, representing the CEA-608 field. |
ccData1 |
number | CEA-608 byte 1. |
ccData2 |
number | CEA-608 byte 2. |
order |
number | A number indicating the order this packet was received in a sequence of packets. Used to break ties in a stable sorting algorithm |
- Source:
Style
Style associated with a cue.
Type:
- {textColor: ?string, backgroundColor: ?string, italics: ?boolean, underline: ?boolean}
- Source: